Windows PowerShell command on Get-command sane-teco2
MyWebUniversity

Manual Pages for UNIX Operating System command usage for man sane-teco2

SANE Scanner Access Now Easy sane-teco2(5)

NAME

sane-teco2 - SANE backend for TECO / RELISYS scanners

DESCRIPTION

The sane-teco2 library implements a SANE (Scanner Access Now

Easy) backend that provides access to some TECO SCSI flatbed

scanners. This backend should be considered beta-quality

software! TECO scanners are sold under various brands like Mustek, Relisys, Piotech, Primax, TRUST. This backend may or may not support yours. The scanners that should work with this backend are: Vendor Model TECO model status

---------------------- -------------- -----------

Mustek ScanMagic 4830S VM3575 untested Primax Jewel 4800 VM356A good Primax Profi 9600 VM6575 basic Primax Profi 19200 VM6586 good Relisys APOLLO Express 3 VM356A basic Relisys APOLLO Express 6 VM6565 good Relisys APOLLO Express 12 ? untested Relisys AVEC II S3 VM3564 good Relisys AVEC Super 3 VM3575 basic Relisys SCORPIO Pro VM6575 good

Relisys SCORPIO Pro-S VM6586 untested

Relisys SCORPIO Super 3 VM3575 good For all these scanners, lineart and gray mode work well. However, most of them do not support more than a handful of resolutions in color mode. See the backend home page (under AUTHOR) for the exact status of each scanner.

Note that the untested scanner will not be directly sup-

ported. You should contact the author for that. The TECO VM number can usually be found at the back of the scanner. It is also part of the FCC ID. The options the backend supports can either be selected through command line options to programs like scanimage or through GUI elements in xscanimage, xsane, quiteinsane or kooka. If you have any success with a scanner not listed here, or

if you have any strange behavior, please report to the back-

end maintainer or to the SANE mailing list. Valid command line options and their syntax can be listed by using

scanimage --help -d teco2

sane-backends 1.0.19Last change: 29 July 2005 1

SANE Scanner Access Now Easy sane-teco2(5)

Scan Mode

--mode

selects the basic mode of operation of the scanner valid choices are Lineart , Gray and Color The Lineart mode is black and white only (1 bit). Gray mode will produce 256 levels of gray (8 bits). Color will produce a 24 bits color image.

--resolution

Lineart and Gray selects the resolution for a scan. The scanner can do all resolutions between 1 and 600, in increments of 1. Color selects the resolution for a scan. The scanner can do only the resolutions listed. All values with ydpi > 300 (300 x 600) or 600 (600 x 1200) result in a wrong proportion for the scan. The

proportion can be adjusted with the following imagemag-

ick command: convert -geometry (dpi/max_xdpi *

100%)x100% max_xdpi is for the vm3575 constant with 300

dpi e.g. 600dpi adjust with: convert -geometry

200%x100%

Geometry options

-l -t -x -y

control the scan area: -l sets the top left x coordi-

nate, -t the top left y coordinate, -x selects the

width and -y the height of the scan area. All parame-

ters are specified in millimeters by default. Enhancement options

--custom-gamma (no custom gamma option for

(color mode only) allows the user to specify a gamma table (see the next 3 parameters).

--red-gamma-table

(color mode only) can be used to download a user defined gamma table for the red channel. The table must be 256 bytes long.

sane-backends 1.0.19Last change: 29 July 2005 2

SANE Scanner Access Now Easy sane-teco2(5)

--green-gamma-table

(color mode only) can be used to download a user defined gamma table for the green channel. The table must be 256 bytes long.

--blue-gamma-table

(color mode only) can be used to download a user defined gamma table for the blue channel. The table must be 256 bytes long.

--white-level-r

(VM3564, VM356A, VM3575 and VM6575 only) Selects what red radiance level should be considered "white", when scanning some sheets by changing the calibration value loaded into the scanner. Scale 0..64 in steps of 1.

--white-level-g

(VM3564, VM356A, VM3575 and VM6575 only) Selects what green radiance level should be considered "white", when scanning some sheets by changing the calibration i value loaded into the scanner. Scale 0..64 in steps of 1.

--white-level-b

(VM3564, VM356A, VM3575 and VM6575 only) Selects what blue radiance level should be considered "white", when scanning some sheets by changing the calibration value loaded into the scanner. Scale 0..64 in steps of 1.

--preview

requests a preview scan. The resolution used for that scan is 50 dpi (for VM356A and VM6575 75 dpi) and the scan area is the maximum allowed. The scan mode is user selected. The default is "no". CONFIGURATION FILE The configuration file /etc/sane.d/teco2.conf supports only one information: the device name to use (eg /dev/scanner). FILES

/usr/lib/sane/libsane-teco2.a

The static library implementing this backend.

sane-backends 1.0.19Last change: 29 July 2005 3

SANE Scanner Access Now Easy sane-teco2(5)

/usr/lib/sane/libsane-teco2.so

The shared library implementing this backend (present on systems that support dynamic loading). ENVIRONMENT

SANE_DEBUG_TECO2

If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity.

SANE_TECO2_CAL_ALGO

Either 0 or 1. Selects the algorithm for the calibra-

tion. A value of 1 seems to give better scans on the VM356A, VM3575. Feedback on it is welcome. For VM3564, VM356A, VM3575, VM6575 default 1. For other supported types default 0. LIMITATIONS The windows TWAIN driver has many more options than this SANE backend. However they are only software adjustments. This backend only implements what the scanner can support.

BUGS

Plenty. Parts of this backend are still under development.

SEE ALSO

sane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)

AUTHORS Frank Zago

http://www.zago.net/sane/#teco2

The package is actively maintained by Gerard Klaver. http://gkall.hobby.nl/teco2.html CREDITS Thanks to:

sane-backends 1.0.19Last change: 29 July 2005 4

SANE Scanner Access Now Easy sane-teco2(5)

a patch to support the VM3564 and VM356A. Gerard Klaver for his relentless VM3575 testings and contributed Mark Plowman for providing the first SCSI traces from a VM3575. VM6586 and for his testing, and to Stefan von Dombrowski for his testing. Andreas Klaedtke for providing the first SCSI traces from a VM656A and for his testing. Nicolas Peyresaubes for providing the first SCSI traces from a Dave Parker for testing the support for the VM6575. Michael Hoeller for testing the support for the VM356A. isys AVEC II S3 firmware 1.09).

Christoph.Hoeffner for testing the support for the VM3564 (Rel-

ATTRIBUTES

See attributes(5) for descriptions of the following attri-

butes:

_________________________________________________________

| ATTRIBUTE TYPE | ATTRIBUTE VALUE |

|____________________|____________________________________|_

| Availability | image/scanner/xsane/sane-backends|

|____________________|____________________________________|_

| Interface Stability| Uncommitted |

|____________________|___________________________________|

NOTES Source for SANE is available on http://opensolaris.org.

sane-backends 1.0.19Last change: 29 July 2005 5




Contact us      |      About us      |      Term of use      |       Copyright © 2000-2019 MyWebUniversity.com ™