Manual Pages for Linux CentOS command on man ndctl-inject-smart
MyWebUniversity

Manual Pages for Linux CentOS command on man ndctl-inject-smart

NDCTL-INJECT-SMART(1) ndctl Manual NDCTL-INJECT-SMART(1)

NAME

ndctl-inject-smart - perform smart threshold/injection operations on a DIMM SYNOPSIS

ndctl inject-smart [] DESCRIPTION A generic DIMM device object, named /dev/nmemX, is registered for each memory device indicated in the ACPI NFIT table, or other platform NVDIMM resource discovery mechanism.

ndctl-inject-smart can be used to set smart thresholds, and inject smart attributes. EXAMPLES

Set smart controller temperature and spares threshold for DIMM-0 to 32C, spares threshold to 8, and enable the spares alarm.

ndctl inject-smart ctrl-temperature-threshold=32 spares-threshold=8 spares-alarm nmem0 Inject a media temperature value of 52 and fatal health status flag for

DIMM-0

ndctl inject-smart media-temperature=52 health=fatal nmem0 OPTIONS

-b, bus= Enforce that the operation only be carried on devices that are attached to the given bus. Where bus can be a provider name or a bus id number.

-m, media-temperature= Inject for the media temperature smart attribute.

-M, media-temperature-threshold= Set for the smart media temperature threshold.

media-temperature-alarm= Enable or disable the smart media temperature alarm. Options are on or off.

media-temperature-uninject Uninject any media temperature previously injected.

-c, ctrl-temperature= Inject for the controller temperature smart attribute.

-C, ctrl-temperature-threshold= Set for the smart controller temperature threshold.

ctrl-temperature-alarm= Enable or disable the smart controller temperature alarm. Options are on or off.

ctrl-temperature-uninject Uninject any controller temperature previously injected.

-s, spares= Inject for the spares smart attribute.

-S, spares-threshold= Set for the smart spares threshold.

spares-alarm= Enable or disable the smart spares alarm. Options are on or off.

spares-uninject Uninject any spare percentage previously injected.

-f, fatal Set the flag to spoof fatal health status.

fatal-uninject Uninject the fatal health status flag.

-U, unsafe-shutdown Set the flag to spoof an unsafe shutdown on the next power down.

unsafe-shutdown-uninject Uninject the unsafe shutdown flag.

-N, uninject-all Uninject all possible smart fields/values irrespective of whether they have been previously injected or not.

-v, verbose Emit debug messages for the error injection process

-u, human Format numbers representing storage sizes, or offsets as human

readable strings with units instead of the default machine-friendly

raw-integer data. Convert other numeric fields into hexadecimal strings. COPYRIGHT

Copyright (c) 2016 - 2018, Intel Corporation. License GPLv2: GNU GPL version 2 http://gnu.org/licenses/gpl.html. This is free software: you are free to change and redistribute it. There is NO WARRANTY, to the extent permitted by law. SEE ALSO

ndctl-list(1),

ndctl 62 11/02/2018 NDCTL-INJECT-SMART(1)




Contact us      |      About us      |      Term of use      |       Copyright © 2000-2019 MyWebUniversity.com ™